Display and controls

Smart double-pole thermosts for electric heating
TH1500RF

Display and controls

Smart double-pole thermosts for electric heating
TH1500RF

État de connexion avec la passerelle
Heure
Affichage secondaire : Température extérieure (Out)
Température ambiante

Changing settings from the device

To change the temperature settings you must:

1

Lower the setpoint temperature to its minimum and keep the  pressed for 10 seconds to access the menu.

2

Press the   or  buttons to change the setting.

3

Press the  and  buttons simultaneously to select the next parameter. Continue to press until the end of the list to exit the menu.

Settings that can be changed from the device

#

NameParameters & settings
1Temp

Temperature format

°C or °F – (default: °C)

2Min

Minimum setpoint

5 °C to 30 °C – (default: 5 °C)

3Max

Maximum setpoint

5 °C to 30 °C – (default: 30 °C)

4BL

Backlight control

ON/OFF (default: ON)

5Load

Load current

0 A to 15 A (1)

6Load

Load power

0 W to 4155 W (2)

1) Lorad current

Reading of the load current, featured in amperes.

2) Puissance de la charge

Reading of the load power connected to the thermostat, featured in watts.

Rechercher

Add your smart double-pole thermostat to your gateway.

You can now move on to configuring your thermostat with your gateway to get more functionality.

You will find below the most common issues you may encounter.

If you still need help, contact Sinopé technical support.