Install a non-programmable thermostat for electric heating

Proceed as follows to install your non-programmable thermostat for electric heating

TH1124NP

Install a non-programmable thermostat for electric heating

Proceed as follows to install your non-programmable thermostat for electric heating

Installing your thermostat
on the wall

Make sure you have all the items that are included in the box

  • Non-programmable thermostat for electric heating
  • Installation guide – English version
  • Installation guide – French version
  • 2 mounting screws
  • 2 wire connectors

You will also need:

  • Phillips screwdriver 
  • Wire stripper (optional)
TH1124NP

Follow the installation steps

Here is a detailed step-by-step guide that will take you through the installation of your electric heating non-programmable thermostat.

The installation of this thermostat must be performed by a certified electrician and comply with the national and local electrical codes and regulations.

The warranty does not cover damage to the thermostat due to improper installation. Special CO/ ALR solderless connectors must be used when connecting with aluminum conductors.

1

Make sure that the breakers for your heating system are off at the main electrical panel to avoid any risk of electric shock

2

Unlock and lift the thermostat cover.

3

Use the provided wire connectors to connect the thermostat wires to the wires in the electrical box.

Note: The wires of this thermostat are non-polarized.

Two-wire installation

Four-wire installation

Make sure to firmly tighten the wire connectors for a secure connection. A loose connection can be a fire hazard. 

4

Use the screws provided to install the thermostat to the electrical box.

Replace the cover and lock.

5

Power up the thermostat.

After switching on the breakers, your Sinopé thermostat should turn on automatically.