Changing advanced settings on the device

To change the thermostat’s settings, you need to:

1

Get the setpoint to its minimum and hold the  button for 10 seconds to access the menu.

2

Press the or button to change the settings.

3

Press the and buttons simultaneously to save and go to the next parameter. Continue to press until the end of the list to exit the menu. 

Advanced settings

Order

Name

Parameters & settingsDisplay
1Scale

Temperature scale

°C or °F (Default: °F)

°F or °C

Cycle length

Control cycle

SHT (short cycle for electric baseboard)
FAN (long cycle for fan forced heater)
(Default: SHT)

SHT

3Setpoint Min

Minimum setpoint

41 °F to 86 °F – (Default: 41 °F)

5 °C to 30 °C

41 °

4Setpoint Max

Maximum setpoint

41 °F to 86 °F – (Default: 86 °F)

5 °C to 30 °C

86 °

5Blacklight

Backlight control

ON, OFF or BED – (Default: ON)

ON (backlight always active, will dim according to ambient light)

OFF (will only turn on when a button is pressed)

BED (bedroom mode – backlight will dim according to ambient light and will turn OFF below 20% of luminosity)

ON

OFF Mode

To put your thermostat in OFF mode, you need to:

1

Hold the buttons and for 10 seconds.

2

To exit the OFF mode, hold the buttons and for 10 seconds or raise/lower the setpoint. 