Learn how to customize your thermostat
intelligent low voltage Zigbee
Learn how to customize your thermostat
smart Zigbee
low voltage
The temperature detected by
the thermostat
The temperature you wish to achieve in the room. You can increase or decrease the setting by pressing the arrows.
The graphical representation of the thermostat’s status. This is where you can see if the thermostat is currently heating.
The thermometer level represents the heating period of the thermostat.
When the thermostat is not in heating mode, the color of the thermostat changes to turquoise.
This is where you can customize and modify the various thermostat settings, which are explained later.
You can view the energy consumption graph for this device here.
You will find more details on consumption graphs in this article:
You can view all the automations that include this device here.
When you have multiple thermostats in the same location, it can be useful to rename your thermostat or assign it to a particular room.
This feature can also be very useful if you use voice assistants like Google Assistant or Alexa .
To do this, you need to access the thermostat settings by pressing the icon in the thermostat screen.
It is also in the settings section that you can change the information that appears on the thermostat screen as well as the backlighting.
Several other configuration parameters allow you to control the actions that can be physically performed on the thermostat, such as locking the keypad and setting maximum and minimum setpoints.
The connected load (in watts) detected by the thermostat is also displayed in the settings configuration section.
The information displayed in the secondary area of the device screen
The temperature format displayed on the thermostat screen
The time format displayed by the device
Always on:
The screen backlight is always on and its intensity adjusts according to the ambient light.
Upon request:
The backlight turns on when you press the thermostat buttons and turns off after 12 seconds.
Enables or disables the device buttons
Unlocked: activates the device buttons.
Locked: disables the device buttons.
Limited: only allows modification of the setpoint. Limits device configuration and disconnection.
The code “LC” is displayed on the thermostat screen if the “Locked” or “Limited” option is selected.
The maximum setpoint temperature available on the thermostat
The minimum setpoint temperature available on the thermostat
Enter the wattage of the heating appliance connected to the thermostat’s auxiliary output. The modified value is used solely for calculating consumption statistics and does not affect the thermostat’s performance.
Control mode using floor or ambient temperature.
The maximum floor temperature limit when in ambient control mode.
The minimum floor temperature limit when in ambient control mode.
The maximum ambient temperature limit when in floor control mode.
Allows you to select the length of the control cycle according to the type of load connected to the thermostat.
Note: If you are using a water system with a long start-up time, you will need to select a longer cycle time.
Note: If you are using a water-based system with a long start-up time, you will need to select a longer cycle time.
If the thermostat does not heat for an extended period (for example, in summer), this function activates the main output for 1 minute every 24 hours to prevent the pump in a hydronic system from seizing up. This function prevents the pump from seizing.
Enter the wattage of the heating appliance connected to the thermostat’s auxiliary output. The modified value is used solely for calculating consumption statistics and does not affect the thermostat’s performance.
You can now start programming your thermostat and creating automations.
Find below the problem you are experiencing to know what to do.
If you still need help , contact Sinopé technical support.