Configure your thermostat
TH1120RF-3000 / TH1120RF-4000

Learn how to customize your Mi-Wi (Legacy)
thermostat for electric heating

Configure your thermostat
TH1120RF-3000 / TH1120RF-4000

Learn how to customize your Mi-Wi (Legacy)
thermostat for electric heating

paramètres
État du thermostat
Termpérature actuelle
Termpérature de consigne
Historique de consommation énergétique
Horaire
Mode

Current temperature

The temperature detected by
the thermostat

Set temperature

The temperature you want to reach in the room. You can increase or decrease the setpoint by pressing the arrows.

Thermostat status

The graphic representation of the state of the thermostat. This is where you can see if the thermostat is currently heating up.

The thermometer level represents the heating period of the thermostat.

When the thermostat is not heating, the thermostat color changes to teal.

Thermostat settings

This is where you can customize and modify the various thermostat settings, which are explained to you later.

Energy consumption history

Here you can view the energy consumption graph for this device.

You can find more details on consumption charts in this article:

Schedules

Programming your Mi-Wi thermostat is done by setting schedules.

You can program up to eight periods per day here.

Modes

You can select different modes for your Mi-Wi thermostat: automatic, manual, frost safe and standby.

See what the properties of each of these modes are.

THE SETTINGS​

Customize the thermostat display in Neviweb

When you have multiple thermostats in one location, it can be handy to rename your thermostat or assign it to a particular room.

This function can also be very useful if you use the Alexa voice assistant.

To do this, you must access the thermostat settings by pressing the icon on the thermostat screen.

Display settings

Settings
Description
Name
Corresponds to the name that will be given to the device in Neviweb
Room
This selection allows devices to be grouped by room to facilitate identification and management.
Add to favorite
Add this device to favorites accessible from the app dashboard

Customize the thermostat screen in Neviweb

It is also in the settings section that you can modify the information that appears on the thermostat screen as well as the backlight.

Several other configuration settings allow you to control actions that can be physically performed on the thermostat, such as locking the keypad and establishing maximum and minimum set points.

The connected load (in watts) detected by the thermostat is also displayed in the settings configuration section.

Configuration settings

Settings
Description
Options
Secondary display
Description

The information displayed in the secondary area of the device screen

Options
Setpoint
Outside Temp.
Temperature format
Description

The temperature format displayed on the thermostat screen

Options
Celcius
Fahrenheit
Time format
Description

The time format featured on the thermostat display

Options
24h - 12h
Backlight
Description

Always ON:

The display backlight is always on, and its intensity adjusts according to the ambient light.

Automatic:

The backlight turns on when you press the thermostats buttons and turns off after 12 sec.

Options
Always ON
Automatic
Early start
Description

The early start functionality can bu used only in Automatic mode.  When enabled, the thermostat determines when to start heating to obtain the desired temperature by the time set in your schedule.

Options
OFF
ON
Main cycle length
Description

Long cycle for fan-forced convector. Short cycle for an electric baseboard.

Options
Long cycle
Short cycle
Keypad
Description

Enables or disables the device’s buttons

Options
Unlocked
Locked
Max. Setpoint
Description

The maximum setpoint temperature available on the thermostat

Options
5 °C to 30 °C
30 °C default
Min. Setpoint
Description

The minimum setpoint temperature available on the thermostat

Options
5 °C to 30 °C
5 °C default
Away setpoint
Description

The setpoint temperature assigned to the thermostat when the away mode is activated

Options
5 °C to 30 °C
Load connected (watts)
Description

The power in watts of the electrical load connected to the device. This value is read automatically by the thermostat and is used to assess energy consumption.

Options
-

Customize the thermostat configuration

Your thermostat allows you to change the length of the
control cycle depending on the type of heater.

Cycle length depending on the type of heater

Type of heater
Description
Electric baseboard
Short
Convector
Short
Fan-forced convector
Long
Radiant ceiling
Short

Enable thermostat alarms in Neviweb


It is possible to receive certain types of alarms by email when your thermostat detects certain anomalies.

Alarms settings

Settings
Description
Options
Temperature below 5 ° C
Description

An alarm message is sent when the ambient temperature drops below 5 ° C.

Options
Disable
Enable ​

Next step

You can now begin to program your thermostat and set schedules.