Configure your TH1400WF
thermostat

Learn how to customize your smart Wi-Fi low voltage thermostat

Configure your TH1400WF thermostat

Learn how to customize your smart Wi-Fi low voltage thermostat​

paramètres
État du thermostat
Termpérature actuelle
Termpérature de consigne
Historique de consommation énergétique
Horaire

Current temperature

The temperature detected by
the thermostat

Set temperature

The temperature you want to reach in the room. You can increase or decrease the setpoint by pressing the arrows.

Thermostat status

The graphic representation of the state of the thermostat. This is where you can see if the thermostat is currently heating up.

The thermometer level represents the heating period of the thermostat.

When the thermostat is not heating, the thermostat color changes to teal.

Thermostat settings

This is where you can customize and modify the various thermostat settings, which are explained to you later.

Energy consumption history

Here you can view the energy consumption graph for this device.

You can find more details on consumption charts in this article:

Schedules

Programming your Wi-Fi thermostat is done setting schedules.

You can program up to eight periods per day here.

Modes

You can select different modes for your Wi-Fi thermostat: automatic, manual and off.

See what are the properties of each of these modes.

the settings

Customize the thermostat display in Neviweb

When you have multiple thermostats in one location, it can be handy to rename your thermostat or assign it to a particular room.

This function can also be very useful if you use voice assistants like Google Assistant or Alexa.

To do this, you must access the thermostat settings by pressing the icon on the thermostat screen.

Display settings

Paramètres
Description
Name
Corresponds to the name that will be given to the device in Neviweb
Room
This selection allows devices to be grouped by room to facilitate identification and management.
Add to favorite
Add this device to favorites accessible from the app dashboard

Customize the thermostat screen in Neviweb

It is also in the settings section that you can modify the information that appears on the thermostat screen as well as the backlight.

Several other configuration settings allow you to control actions that can be physically performed on the thermostat, such as locking the keypad and establishing maximum and minimum set points.

The connected load (in watts) detected by the thermostat is also displayed in the settings configuration section.

Configuration settings

Settings
Description
Options
Secondary display
Description

The information displayed in the secondary area of the device screen

Options
Automatic
Setpoint
Outside Temp.
Temperature unit
Description

The temperature format displayed on the thermostat screen

Options
Celsius
Fahrenheit
Time format
Description

The time format featured on the thermostat display

Options
24h - 12h
Backlight
Description

Always ON:

The display backlight is always on, and its intensity adjusts according to the ambient light.

On Demand:

The backlight turns on when you press the thermostats buttons and turns off after 12 sec.

Options
Always ON
On Demand
Early start
Description

The early start functionality can bu used only in Automatic mode.  When enabled, the thermostat determines when to start heating to obtain the desired temperature by the time set in your schedule.

Options
OFF
ON
Keypad
Description

Enables or disables the device’s buttons

Options
Unlocked
Locked
Max. Setpoint
Description

The maximum setpoint temperature available on the thermostat

Options
5 °C to 36 °C
36 °C default
Min. Setpoint
Description

The minimum setpoint temperature available on the thermostat

Options
5 °C to 36 °C
5 °C default
Away setpoint
Description

The setpoint temperature assigned to the thermostat when the away mode is activated

Options
5 °C to 36 °C
Load connected (watts)
Description

Enter the wattage of the heating device connected to the thermostat’s auxiliary output. The modified value will only be used for the calculation of the consumption statistics and does not affect the performance of the thermostat in any way.

Options
Enter the connected load manually

Customize advanced thermostat settings in Neviweb

Your thermostat allows you to choose the control mode and several advanced parameters such as the control of a 2nd stage of heating.

Advance settings

Settings
Description
Options
Control mode
Description

Control mode using floor or ambient temperature.

Options
Floor
Ambient
Floor default
Max. floor temperature
Description

The maximum floor temperature limit of the floor when in ambient control mode.

Options
OFF
5 °C to 36 °C
OFF default
Min. floor temperature​
Description

The minimum floor temperature limit of the floor when in ambient control mode.

Options
OFF
5 °C to 36 °C
OFF default
Ambient limit
Description

The maximum ambient temperature limit when in floor control mode.

Options
OFF
5 °C to 36 °C
OFF default
Probe type
Description

The floor sensor supplied with Neviweb compatible thermostats is 10 K Ω. If you are replacing a thermostat from another manufacturer, verify the value of the probe at 25 ° C. Our thermostats are compatible with 10 K Ω and 12 K Ω floor sensors at 25 ° C.

Options
10 K
12 K ​
Main cycle length
Description

Selects the length of the control cycle according to the type of load connected to the thermostat.

 

15 seconds: baseboard or convector controlled through a SSR 

5 minutes: baseboard, fan-forced convector controlled through a SSR 

10 minutes: baseboard, fan-forced convector controlled through a mechanical relay

15 minutes: electirc floor with mechanical relay, electric hot-water system or hot water pump

20 minutes: gas or oil system

 

If you’re using a hot water system requiring a long delay to start, you’ll need to increase the cycle length.

Options
15 sec
5 min
10 min
15 min
20 min
25 min
30 min
Auxiliary cycle length
Description

Selects the length of the control cycle according to the type of load connected to the thermostat.

 

OFF: deactivated

15 seconds: baseboard or convector controlled through a SSR 

5 minutes: baseboard, fan-forced convector controlled through a SSR 

10 minutes: baseboard, fan-forced convector controlled through a mechanical relay

15 minutes: electirc floor with mechanical relay, electric hot-water system or hot water pump

20 minutes: gas or oil system

 

If you’re using a hot water system requiring a long delay to start, you’ll need to increase the cycle length.

Options
OFF
15 sec
5 min
10 min
15 min
20 min
25 min
30 min
Pump protection
Description

When the thermostat is not heating for an extended period (for example: during summer), this parameter will activate the main output during 1 minute every 24 hours to ensure the hydronic system pump does not seize.

Options
ON
OFF
Aux. load connected (watts)
Description

Enter the wattage of the heating device connected to the thermostat’s auxiliary output. The modified value will only be used for the calculation of the consumption statistics and does not affect the performance of the thermostat in any way.

Options
Enter the connected load manually

Next step

You can now begin to program your thermostat and set schedules.