Learn how to customize your smart Wi-Fi low voltage thermostat
Learn how to customize your smart Wi-Fi low voltage thermostat
The temperature detected by
the thermostat
The temperature you want to reach in the room. You can increase or decrease the setpoint by pressing the arrows.
The graphic representation of the state of the thermostat. This is where you can see if the thermostat is currently heating up.
The thermometer level represents the heating period of the thermostat.
When the thermostat is not heating, the thermostat color changes to teal.
This is where you can customize and modify the various thermostat settings, which are explained to you later.
Here you can view the energy consumption graph for this device.
You can find more details on consumption charts in this article:
Programming your Wi-Fi thermostat is done setting schedules.
You can program up to eight periods per day here.
You can select different modes for your Wi-Fi thermostat: automatic, manual and off.
See what are the properties of each of these modes.
When you have multiple thermostats in one location, it can be handy to rename your thermostat or assign it to a particular room.
This function can also be very useful if you use voice assistants like Google Assistant or Alexa.
To do this, you must access the thermostat settings by pressing the icon on the thermostat screen.
It is also in the settings section that you can modify the information that appears on the thermostat screen as well as the backlight.
Several other configuration settings allow you to control actions that can be physically performed on the thermostat, such as locking the keypad and establishing maximum and minimum set points.
The connected load (in watts) detected by the thermostat is also displayed in the settings configuration section.
The information displayed in the secondary area of the device screen
The temperature format displayed on the thermostat screen
The time format featured on the thermostat display
Always ON:
The display backlight is always on, and its intensity adjusts according to the ambient light.
On Demand:
The backlight turns on when you press the thermostats buttons and turns off after 12 sec.
The early start functionality can bu used only in Automatic mode. When enabled, the thermostat determines when to start heating to obtain the desired temperature by the time set in your schedule.
Enables or disables the device’s buttons
The maximum setpoint temperature available on the thermostat
The minimum setpoint temperature available on the thermostat
The setpoint temperature assigned to the thermostat when the away mode is activated
Enter the wattage of the heating device connected to the thermostat’s auxiliary output. The modified value will only be used for the calculation of the consumption statistics and does not affect the performance of the thermostat in any way.
Your thermostat allows you to choose the control mode and several advanced parameters such as the control of a 2nd stage of heating.
Control mode using floor or ambient temperature.
The maximum floor temperature limit of the floor when in ambient control mode.
The minimum floor temperature limit of the floor when in ambient control mode.
The maximum ambient temperature limit when in floor control mode.
The floor sensor supplied with Neviweb compatible thermostats is 10 K Ω. If you are replacing a thermostat from another manufacturer, verify the value of the probe at 25 ° C. Our thermostats are compatible with 10 K Ω and 12 K Ω floor sensors at 25 ° C.
Selects the length of the control cycle according to the type of load connected to the thermostat.
15 seconds: baseboard or convector controlled through a SSR
5 minutes: baseboard, fan-forced convector controlled through a SSR
10 minutes: baseboard, fan-forced convector controlled through a mechanical relay
15 minutes: electirc floor with mechanical relay, electric hot-water system or hot water pump
20 minutes: gas or oil system
If you’re using a hot water system requiring a long delay to start, you’ll need to increase the cycle length.
Selects the length of the control cycle according to the type of load connected to the thermostat.
OFF: deactivated
15 seconds: baseboard or convector controlled through a SSR
5 minutes: baseboard, fan-forced convector controlled through a SSR
10 minutes: baseboard, fan-forced convector controlled through a mechanical relay
15 minutes: electirc floor with mechanical relay, electric hot-water system or hot water pump
20 minutes: gas or oil system
If you’re using a hot water system requiring a long delay to start, you’ll need to increase the cycle length.
When the thermostat is not heating for an extended period (for example: during summer), this parameter will activate the main output during 1 minute every 24 hours to ensure the hydronic system pump does not seize.
Enter the wattage of the heating device connected to the thermostat’s auxiliary output. The modified value will only be used for the calculation of the consumption statistics and does not affect the performance of the thermostat in any way.
You can now begin to program your thermostat and set schedules.
You will find below the most common issues you may encounter.
If you still need help, contact Sinopé technical support.