Aucun article dans le panier.

Technical specifications of your thermostat
TH1121RF-3000 / TH1121RF-4000

THERMOSTAT FEATURES*

* These features are available in Neviweb and require the use of the GT125 gateway. Features may vary from platform to platform.

fonctionnalités

SCENES

Activate personalized ambiances according to the time of the day, events or activity

SCHEDULES

Program different schedules for each day of the week, up to 6 periods per day

ENERGY REPORTS

See your consumption and savings in real-time

GEOFENCING

Trigger actions based on your presence

VOICE ASSISTANTS

Compatible with Amazon Alexa

TECHNICAL SPECIFICATIONS

Operating voltage: 120/208/240 Vac, 60 Hz

Bilateral triode switch (triac)

MAXIMUM LOAD (RESISTIVE LOAD ONLY):

TH1121RF-3000

Min. 0.5 A / 120 W @ 240 Vac

Max. 12.5 A / 3000 W @ 240 Vac

TH1121RF-4000

Min. 0.5 A / 120 W @ 240 Vca 

Max. 16.7 A / 4000 W @ 240 Vca

Températures

Setpoint range: 5 °C to 30 °C (41 °F to 86 °F)

Display range: 0 °C to 70 °C (32 °F to 99 °F)

Resolution: ±0.5 °C (±1 °F)

Storage: -20 °C to 50 °C (-4 °F to 122 °F)

3-year warranty

communication

Protocol: Mi-Wi 

certifications

STANDARD

Conforms to CSA-C828-13 

dimensions

TH1121RF-3000

Lenght: 12.7 cm (5 po)

Width: 8.5 cm (3,35 po)

Depth: 2.8 cm (1 po)

TH1121RF-4000

Lenght: 12.7 cm (5 po)

Width: 11.5 cm (4,53 po)

Depth: 3.2 cm (1,26 po)

Choisissez une langue

Ce site est offert dans d'autre langue. Veuillez choisir votre préférence.

Continuer