To change the temperature settings or the control cycle, you must:
Lower the setpoint temperature to its minimum and keep the button pressed for 10 seconds to access the menu.
Press the or buttons to change the setting.
Press the and buttons simultaneously to select the next parameter. Continue to press until the end of the list to exit the menu.
# | Name | Parameters & settings |
1 | Load | Load power 0 watt to 3600 watt |
2 | Display | Temperature format °C or °F – (default: °C) |
3 | Control | Control mode A (Air), F (Floor) – (default: F) |
4 | Limit Floor Max | Maximum floor temperature (Visible only in A mode) 5 °C to 36 °C – (default: OFF) |
5 | Aux | Assignment of auxiliary output OFF, EXP, 15 sec, 15 min – (default: OFF) |
6 | Sensor | Floor sensor 10K or 12K – (default: 10K) |
You can now add your thermostat to your platform or voice control to your thermostat using your favorite voice assistant.